Copyright 2026 Liu'an Xinsheng Electric Co., Ltd. All Rights Reserved. Anhui ICP25506798 | XML Sitemap | Robots
We supply KYN61-40.5 armored removable AC metal-enclosed switchgear, 40.5kV indoor high voltage switch cabinet with five-prevention interlock, modular compartment structure for power plant and substation power distribution.
KYN61-40.5 armored removable switchgear adopts a modular compartmentalized structure, divided into four independent sealed compartments: busbar compartment, circuit breaker compartment, cable compartment and relay instrument compartment. The fully isolated structural design effectively prevents fault expansion and phase-to-phase interference, ensuring stable and safe system operation. The whole cabinet is assembled with high-strength aluzinc-coated steel plates, featuring high structural rigidity, precise dimensional matching and excellent interchangeability.
The switchgear supports flexible configuration of mainstream high-voltage components to meet diverse project demands, including: ZN85-40.5 vacuum circuit breaker, SF6 circuit breaker, earthing switch, insulated busbar, current transformers (CT), voltage transformers (VT), high-voltage live display devices, and complete electrical & mechanical interlock components. All core parts are professionally installed and calibrated to guarantee stable switching performance and long service life.
The equipment adopts a removable handcart-type structure with flexible push-pull operation and high interchangeability. The handcart operates smoothly with accurate positioning, facilitating convenient on-site installation, inspection and maintenance. The cabinet body adopts bending and bolted assembly technology without welding deformation, realizing high overall flatness and structural stability. Independent compartment layout isolates live parts effectively, greatly reducing maintenance risks.
KYN61-40.5 switchgear is equipped with a complete five-prevention interlock system integrating mechanical and electrical dual protection, realizing foolproof operation and eliminating misoperation hazards:
1. The circuit breaker can only be closed in the test position or working position;
2. Once the circuit breaker is closed, the handcart is mechanically locked and cannot be moved;
3. The cabinet door can only be opened after the earthing switch is closed;
4. The earthing switch is prohibited from closing when the busbar or cable compartment is live;
5. Live compartments are equipped with locking protection to prevent accidental entry and misoperation, ensuring full operational safety.
a. Optional busbar types: insulated rectangular copper busbar, D-type busbar
b. Standard international color coding for phase sequence identification and safe wiring
This KYN61-40.5 armored removable metal-enclosed switchgear adopts high-standard air composite insulation structure, with sufficient creepage distance and excellent high-voltage insulation performance to adapt to complex and harsh operating environments. The integral aluzinc steel plate cabinet features anti-corrosion, anti-rust and high structural stability, reaching a high protection grade. Equipped with professional pressure relief channels, it can quickly release internal arc fault pressure to protect equipment and personnel safety.
With dual mechanical and electrical interlock design, the equipment achieves comprehensive five-prevention safety protection. The removable handcart structure simplifies daily maintenance and replacement of core components, reducing operation and maintenance costs. The compact modular layout saves installation space, supporting single busbar and single busbar sectional connection schemes to meet diversified high-voltage power distribution demands for industrial and municipal projects.
This 40.5kV armored removable switchgear is designed for indoor installation and applicable under the following standard environmental conditions:
1. Altitude: ≤ 1,000 meters above sea level;
2. Ambient temperature: -25°C to +40°C;
3. Relative humidity: Daily average ≤ 95%, monthly average ≤ 90%;
4. Seismic intensity: ≤ 8 degrees;
5. Site conditions: The installation site must be free from fire hazards, explosion risks, severe contamination, chemical corrosion and intense vibration.
| Product Name | KYN61-40.5 Type Armored Removable AC Metal-Enclosed Switchgear |
| Category | High Voltage Switchgear |
| Brand | Duanlu Electric |
| Manufacturer | Duanlu Electric Co., Ltd. |
| Place of Origin | Anhui, China |
| Certifications | ISO 9001, ISO 14001, CE, IEC compliant |
| Warranty | 12-24 months (extendable) |
| Customization | OEM/ODM available |
| MOQ | 1 unit (sample) / 5-10 units (bulk) |
Our KYN61-40.5 Type Armored Removable AC Metal-Enclosed Switchgear is widely used in:
A: All our products are certified with ISO 9001, ISO 14001, CE, and comply with IEC standards. We can also provide specific certifications required by your local market.
A: We provide a standard 12-month warranty from shipment date, with extended warranty up to 24 months. All products undergo strict pre-shipment testing.
A: Yes, we offer full OEM/ODM services including custom design, branding, and packaging. Our R&D team can develop products according to your technical specifications.
A: MOQ is typically 1 unit for samples and 5-10 units for bulk orders of standard High Voltage Switchgear. Custom designs may have different MOQ requirements.
A: Standard products: 15-25 days. Custom products: 30-45 days depending on specifications. We also keep stock for popular models for faster delivery.
A: We accept T/T (30% deposit, 70% balance before shipment), L/C at sight, and Western Union for samples. Other terms negotiable for long-term partners.
Our engineering team will respond within 24 hours with detailed pricing and technical specifications.